Shell form Cast aluminum casing with cooling
Working power supply 2:AC220V(±10%); 4:DC24V(DC18V~DC30V)
Power waste No load ≤ 10W
Vertical scanning angle of view 30°; 50°Settable models of 30 ° and 50 ° can be set and selected on site.
Response time 2ms
Special output response time Increase the relay by about 7ms; MOS optocoupler increases by about 1ms
Analog current output 4-20mA (maximum load 500 Ω) output mode is determined by the analog output mode
Analog voltage output The output mode of 0-10V (maximum 10mA) is determined by the analog output mode
Minimum detection temperature 350 (normal sensitivity); 250 (high sensitivity)
Display screen 1.54 "high-definition OLED screen
Signal energy intensity 15 level LED light column.
Signal energy intensity output 0-10V analog voltage output, corresponding to the corresponding signal strength

  • Product Details

1.0Overview
An infrared scanning loop detector based on high-precision measurement detects infrared radiation sources located in a vertical field of view area (very narrow horizontal field of view) of 30 ° or 50 °, and outputs an analog quantity (4-20mA current and 0-10V voltage) proportional to the angle position of the heat source in its vertical field of view. It can be used for loop control and measurement in the metallurgical industry steel rolling process.

This detector is a scanning loop detector that is insensitive to the distance of the heat source target and can be installed very far from the measured object. This detector can detect objects with a minimum temperature of 250 .
This detector uses an OLED display screen, and various parameters of the detector’s operation are fully displayed on the display screen, allowing users to have a clear understanding of the operating status at a glance.

Mainly applicable to:
✸Loop adjustment of bar, wire, and hot strip rolling mills;
✸Strip width control;
✸Central positioning of strip and other products
✸The position of the shear head and tail is used for optimizing the action of the profile rolling mill;
✸Edge position control of continuous casting machine and strip

1.0.1 Scanning principle

The optical area of this detector is scanned by a rotating drum with a polyhedral mirror. If a hot metal passes through the field of view of the detector and the detected infrared radiation is reflected onto the photocell, the internal processing circuit converts the optical signal into an electrical signal. By comparing it with the threshold level, a switching value is output. At the same time, the internal processing circuit calculates the position of the infrared radiation source in the entire scanning area and outputs a set of analog quantities (4-20mA current signal and 0-10V voltage signal) corresponding to the percentage of the scanning area, The process is shown in the following figure:

 

 

 

 

 

 

 

Technical parameters

Shell form Cast aluminum casing with cooling
Working power supply 2:AC220V(±10%); 4:DC24V(DC18V~DC30V)
Power waste No load ≤ 10W
Vertical scanning angle of view 30°; 50°Settable models of 30 ° and 50 ° can be set and selected on site.
Response time 2ms
Special output response time Increase the relay by about 7ms; MOS optocoupler increases by about 1ms
Analog current output 4-20mA (maximum load 500 Ω) output mode is determined by the analog output mode
Analog voltage output The output mode of 0-10V (maximum 10mA) is determined by the analog output mode
Minimum detection temperature 350 (normal sensitivity); 250 (high sensitivity)
Display screen 1.54 “high-definition OLED screen
Signal energy intensity 15 level LED light column.
Signal energy intensity output 0-10V analog voltage output, corresponding to the corresponding signal strength
Action threshold 15 LED light columns, set different signal action thresholds.

It can be adjusted by the panel potentiometer, rotating counterclockwise, with an adjustable range of 2-14 from low to high, corresponding to the action threshold of signal strength. It can also be adjusted by setting the external action threshold pin with an external 10K potentiometer to 0V or an external control voltage of 0-10V-3mA (external action threshold control priority). 0V (potentiometer 0 Ω) corresponds to 2nd gear, and 10V (potentiometer 10K) corresponds to 14th gear.

Signal sensitivity N: Normal sensitivity; H: High sensitivity;

The minimum detection temperature for ordinary sensitivity is 350 .

The minimum detection temperature for high sensitivity is 250 .

OUTPUT Relay(Z) Maximum contact capacityAC 250V 10ADC 30V 10A
LEVEL(C) High push pull level; Maximum load current 100mA;
MOS OptoCoupler(G) Maximum input working voltage ≤ 400V AC/DC, maximum load current 60mA
Signal energy alarm Normal: High push pull level; Alarm: Low push pull level, maximum load 100mA
Fault Alarm Normal: High push pull level; Alarm: Low push pull level, maximum load 100mA
Self Test Button self check or external passive switch control self check
Laser assisted aiming 520nm green line laser, 5mW
Insulation resistance DC500V≥20MΩ
Circuit protection DC input polarity protection; Level output short circuit and overload protection;
operation temperature -25 ℃~+70 ℃; -25 ℃~+120 ℃ with water cooling
cooling water Pressure 0.1-0.2MPa, flow rate 1-5L/min
Purge air Pressure 0.05-0.1MPa, flow rate 4-16L/min
protection grade IP66
weight 6.8kg

 