Loop Detector Used to detect the position of the loop measurement
Jan .27.2026
Views
Technical parameters
| Shell form | Cast aluminum casing with cooling | |
| Working power supply | 2:AC220V(±10%); 4:DC24V(DC18V~DC30V); | |
| Power waste | No load ≤ 10W | |
| Vertical scanning angle of view | 30°; 50°;Settable models of 30 ° and 50 ° can be set and selected on site. | |
| Response time | 2ms ; | |
| Special output response time | Increase the relay by about 7ms; MOS optocoupler increases by about 1ms | |
| Analog current output | 4-20mA (maximum load 500 Ω) output mode is determined by the analog output mode | |
| Analog voltage output | The output mode of 0-10V (maximum 10mA) is determined by the analog output mode | |
| Minimum detection temperature | 350 ℃ (normal sensitivity); 250 ℃ (high sensitivity) | |
| Display screen | 1.54 “high-definition OLED screen | |
| Signal energy intensity | 15 level LED light column. | |
| Signal energy intensity output | 0-10V analog voltage output, corresponding to the corresponding signal strength | |
| Action threshold | 15 LED light columns, set different signal action thresholds. It can be adjusted by the panel potentiometer, rotating counterclockwise, with an adjustable range of 2-14 from low to high, corresponding to the action threshold of signal strength. It can also be adjusted by setting the external action threshold pin with an external 10K potentiometer to 0V or an external control voltage of 0-10V-3mA (external action threshold control priority). 0V (potentiometer 0 Ω) corresponds to 2nd gear, and 10V (potentiometer 10K) corresponds to 14th gear. | |
| Signal sensitivity | N: Normal sensitivity; H: High sensitivity; The minimum detection temperature for ordinary sensitivity is 350 ℃. The minimum detection temperature for high sensitivity is 250 ℃. | |
| OUTPUT | Relay(Z) | Maximum contact capacity:AC 250V 10A, DC 30V 10A |
| LEVEL(C) | High push pull level; Maximum load current 100mA; | |
| MOS OptoCoupler(G) | Maximum input working voltage ≤ 400V AC/DC, maximum load current 60mA | |
| Signal energy alarm | Normal: High push pull level; Alarm: Low push pull level, maximum load 100mA | |
| Fault Alarm | Normal: High push pull level; Alarm: Low push pull level, maximum load 100mA | |
| Self Test | Button self check or external passive switch control self check | |
| Laser assisted aiming | 520nm green line laser, 5mW | |
| Insulation resistance | DC500V,≥20MΩ | |
| Circuit protection | DC input polarity protection; Level output short circuit and overload protection; | |
| operation temperature | -25 ℃~+70 ℃; -25 ℃~+120 ℃ with water cooling | |
| cooling water | Pressure 0.1-0.2MPa, flow rate 1-5L/min | |
| Purge air | Pressure 0.05-0.1MPa, flow rate 4-16L/min | |
| protection grade | IP66 | |
| weight | 6.8kg | |